Used Shimadzu SIL-HTA Autosampler
Shimadzu SIL-HTa Autosampler (non-chilled).
Features
High throughput
The SIL-HTa maximizes analysis throughput with fast sample injection and high sample capacity. Injection speed is 15 seconds for injecting samples of 10µL.
Excellent repeatability
The SIL-HTa uses a
needle-in-the-flow-path injection design (also called direct injection
method or total volume injection method) and a high-performance
measuring pump (6nL step resolution) for enhanced accuracy. This results
in superior repeatability over conventional autosamplers. In addition,
precious samples are not wasted since the total volume aspirated is
injected.
Specification:
Shimadzu SIL-HTa Sample Injection
System
Total sample injection, variable sample
injection system (zero sample loss during
injection).
Shimadzu SIL-HTa Settable Range Of Injection Volumes
0.1
to 1000µL (standard), or 1 to 20000µL (option) (0.10µL steps from 0.1 to
0.90µL, and 10µL steps from 1 to 20000µL)
Shimadzu SIL-HTa Sample Processing
Capability
With 1-mL vials: 350
With
1.50mL vials: 210(SIL-HTa), 140(SIL-HTc)
With 4-mL
vials:100
With micro plates:4 (96 wells: 384, 384 wells:
1536)
With deep-well plates: 4 (96 wells: 384, 384 wells:
1536)
Shimadzu SIL-HTa Injection Volume Repeatability
RSD: 0.3%
max. (at 100µL injection)
Shimadzu SIL-HTa Cross Contamination
0.01% max. (for analysis of naphthalene)
Number Of Injections
1-99 times per
sample
Input/Output Terminals: External start input: 1, Error input: 3, External output(EVENT 1,2,3,4): 4, Output for external control (AC Remote):1, Optical link: (for Chromatopac), 8 (for LC unit control), RS-232C: 1 (for PC connection)
Pump Control: Solvent delivery models: isocratic, high-pressure gradient, low-pressure gradient, constant pressure solvent delivery. Programs: flow volume, pressure, concentration, upper pressure limit, lower pressure limit, linear step, index function (all are multiple steps).
Autosampler Control: Sample injection volume, number of repeated analyses, analysis time, analysis file unmber, etc.
Shimadzu SIL-HTa Specifications
Operating pH Range: pH: 1 to 14 standardWetted Surface Material: SUS316, PEEK, Ceramics
Operating voltage: 230V
Dimensions: 540 (W) x 500 (D) x 415 (H) mm
Weight: 40kg
Please enquire for full pricing on this excellent instrument.
Warranty Terms & Conditions For Used Equipment
Note: Our warranty terms quoted for this instrument apply to mainland UK customers. For clients outside of this locale, please enquire at point of sale.
Jaytee Biosciences Ltd warranty all reconditioned instruments for a pre-agreed period. This period can be from 30 days to 1 year from the date of installation / delivery of the instrument. Generally newer equipment has a longer warranty than older equipment.
Additional warranty periods can be negotiated at the time of purchase if required.
The list below outlines the items covered by our warranty:
Parts Included In Warranty
- Electronic Assemblies – e.g. PCB’s, Transducers, Interface Cards
- Mechanical Assemblies – e.g. Pump Drive assemblies, XYZ Transport Systems
- Power Supplies – e.g Low and High Voltage Supplies, Lamp Supplies, Cases, Metalwork and Enclosures.
- Major assemblies – PCB’s, Power Supplies, and Displays etc covered for warranty term.
Typical Parts NOT Included In Warranty (autosamplers)
- Needle
- Needle Seat
- Needle Seat Holder
- Rotor Seal
- Stator Face
- Isolation Seal
- Plunger
- Plunger Seals
- Syringes
- Wetted Path Components
- Software Updates
- Tubing and Fittings
- Capillaries
- Consumable Parts
- Tools
Enquire
Send us your details and one of our engineers will get back to you with availability and pricing. Alternatively, call us, quoting "st2656", on +44 (0)1227 265333.